The paper built a two-phase flow model in rectangular secondary sedimentation tanks and resolved the model by use of the computational fluid dynamics software Fluent. The results showed that the distribution of flow velocity is not uniform, and MLSS diameter has no effect on the distribution of flow velocity of MLSS. It has some guidance for wastewater treatment.