文章摘要
赵智超, 张为堂, 崔 鹏, 黄剑明, 史文燕, 陈永志.生物接触氧化法-人工湿地处理常低温生活污水Journal of Water Resources and Water Engineering[J].,2018,29(5):28-34
生物接触氧化法-人工湿地处理常低温生活污水
BCO-constructed wetland treatment of domestic sewage under normal and low temperatures
  
DOI:10.11705/j.issn.1672-643X.2018.05.05
中文关键词: 生物接触氧化法(BCO)-人工湿地; 常低温生活污水; 水力停留时间; 水力负荷  污水处理
英文关键词: biological contact oxidation(BCO)-constructed wetland  domestic sewage under normal and low temperatures  hydraulic retention time(HRT)  hydraulic loading rate(HLR)  waste water treatment
基金项目:国家自然科学基金项目(51668033) ;环境工程甘肃省高等学校特色专业项目(101004);兰州交通大学教改重点项目
Author NameAffiliation
ZHAO Zhichao1, ZHANG Weitang2, CUI Peng3, HUANG Jianming1, SHI Wenyan1, CHEN Yongzhi1 (1.兰州交通大学 环境与市政工程学院 甘肃 兰州 730070 2.北控水务(中国)投资有限公司北京 100124 3.成都市建筑设计研究院 四川 成都 610015) 
Hits: 1729
Download times: 1029
中文摘要:
      采用生物接触氧化法(BCO)-人工湿地组合工艺处理常低温生活污水,当BCO的气水比为7∶1、回流比为100%、人工湿地的水力停留时间(HRT)为9 h,人工湿地的水力负荷(HLR)为3.65 m3/(m2/d)时,在常温下(22~27℃),组合工艺出水COD、NH+4—N、TN和PO43-—P分别为14.60、1.40、12.70和0.43 mg/L,出水满足《城镇污水处理厂污染物排放标准》(GB 18918-2002)一级A标准;而低温下(7~12℃),组合工艺出水COD、NH+4—N、TN和PO43-—P分别为29.60、9.90、19.90和0.88 mg/L。保持气水比和回流比不变,控制低温下BCO的HRT为12 h,人工湿地的HLR为2.74 m3/(m2/d)时,组合工艺出水COD、NH+4—N、TN和PO43-—P为18.40、6.17、14.17和0.66 mg/L,去除率分别为90.60%、87.80%、75.40% 和85.30%。结果表明:常、低温下该组合工艺均能够实现污染物的良好去除,为实际工程应用提供参考。
英文摘要:
      The combined process of BCO-constructed wetland was applied to treat domestic sewage under normal and low temperatures. When the ratio of air to water was 7∶1, the ratio of reflux was 100%, the hydraulic retention time(HRT) was 9h and the hydraulic load rate(HLR) of constructed wetland was 3.65 m3/(m2/d), the combined process effluent concentrations of COD、NH+4—N、TN and PO43-—P were 14.60,1.40,12.70 and 0.43mg/L respectively at normal temperature (22-27℃), which could meet the first class A standards of “Discharge standard of pollutants for municipal wastewater treatment plant”(GB 18918-2002) of China. At low temperature (7-12℃), the combined process effluent concentrations of COD,NH+4—N,TN and PO43-—P were 29.60,9.90,19.90 and 0.88mg/L respectively. When the ratio of air to water and reflux remained unchanged, the HRT of BCO at 12 h and the HLR of constructed wetland of 2.74 m3/(m2/d), the combined process effluent concentrations of COD、NH+4—N、TN and PO43-—P were 18.40,6.17,14.17 and 0.66mg/L, the corresponding removal rates were 90.60%,87.80%,75.40% and 85.30%. The results showed that the combined process could achieve a good removal of pollutants under normal and low temperatures, which provided a theoretical basis for practical engineering applications.
View Full Text   View/Add Comment  Download reader
Close
function PdfOpen(url){ var win="toolbar=no,location=no,directories=no,status=yes,menubar=yes,scrollbars=yes,resizable=yes"; window.open(url,"",win); } function openWin(url,w,h){ var win="toolbar=no,location=no,directories=no,status=no,menubar=no,scrollbars=yes,resizable=no,width=" + w + ",height=" + h; controlWindow=window.open(url,"",win); } &et=BE45507629CF6F9D7C7B7BF9E4E3A0E62BD6EB328E612DFAABDD5FA62B8C2446A087C0C1A29CB81B38B7DCB6791A63F35E437C4CFAC087C1EFC67C31AF37BB207561AE062289EC73B6B36EF0E057B921DE438F362B39F3B4&pcid=5B3AB970F71A803DEACDC0559115BFCF0A068CD97DD29835&cid=3ECA06F115476E3F&jid=BC473CEDCB8CE70D7B12BDD8EA00FF44&yid=EA357AD73C8E13BC&aid=0B4BF5AC87809E484814C28271E416F5&vid=&iid=94C357A881DFC066&sid=D3E34374A0D77D7F&eid=339D79302DF62549&fileno=20180505&flag=1&is_more=0">