文章摘要
陈建锋,周天华,孙彬生.轴心受压钢柱火灾后稳定承载力研究Journal of Water Resources and Water Engineering[J].,2013,24(4):71-73
轴心受压钢柱火灾后稳定承载力研究
Study on stability bearing capacity of steel column under axial compression after fire
Received:April 06, 2013  
DOI:10.11705/j.issn.1672-643X.2013.04.017
中文关键词: 轴心受压钢柱  火灾后  稳定承载力  非均质材料  等效截面法
英文关键词: steel column under axial compression  after fire  stability bearing capacity  heterogeneous material  equivalent section method
基金项目:中国博士后科学基金资助(2011M501428); 中央高校基本科研业务费专项资金(CHD2012TD012)
Author NameAffiliation
CHEN Jianfeng School of Civil Engineering, Chang''an University, Xi''an 710061, China 
ZHOU Tianhua School of Civil Engineering, Chang''an University, Xi''an 710061, China 
SUN Binsheng Binxian Administration Bureau of House, Xianyang 713500, China [KH*3D] 
Hits: 1892
Download times: 1178
中文摘要:
      轴心受压钢柱在经历火灾损伤后,构件截面材质呈现非均质力学性态,构件受力状态发生改变。为研究其火灾后剩余承载力,以工程中常用的H形截面轴心受压钢柱为研究对象,考虑高温后材料的强度变化、温度场不均匀对材料特性的影响,构件截面刚度退化等因素,采用等效截面法,分析了单面受火轴心受压钢柱火灾后的偏心效应。提出偏心距及附加弯矩的计算方法,进一步给出轴心受压钢柱火灾后剩余承载力计算公式,并通过算例分析,验证了该方法的合理性。该法不仅可用于单面受火轴压钢柱火灾后剩余承载力计算,也可为类似研究提供新思路。
英文摘要:
      The section of steel column under axial compression presents the state of heterogeneous mechanics and its load condition changes after experiencing fire damage. Taking H-section steel column under axial compression commonly used in engineering for study object, in order to study the residual load bearing capacity after fire and consider the strength change of the material after high temperature and the influence of non-uniform temperature field on material properties and the stiffness degradation of member section, the eccentric effect of steel column under axial compression exposure to one-side fire was analyzed by using the method of equivalent section. The paper proposed calculation methods of the eccentricity and additional moment and further given a formula of residual bearing capacity of the column after fire. The rationality of the calculation methods was verified by the analysis of a calculation example. The method can be used not only to calculate the stability bearing capacity of steel column exposed to one-side fire under axial compression after fire, but also to provide new ideas for similar studies.
View Full Text   View/Add Comment  Download reader
Close
function PdfOpen(url){ var win="toolbar=no,location=no,directories=no,status=yes,menubar=yes,scrollbars=yes,resizable=yes"; window.open(url,"",win); } function openWin(url,w,h){ var win="toolbar=no,location=no,directories=no,status=no,menubar=no,scrollbars=yes,resizable=no,width=" + w + ",height=" + h; controlWindow=window.open(url,"",win); } &et=08EE5A5866ACE44065B72678539DFAE4E5147B9204A0DAF3740B2AC05124B37D127CF3D9C6C3AFEFD1B1D2A95A9E94FA864A257BA1379198480A1086BF0D187605DD949E859C21C95D30C67DBAE7518A85BA9DA2F3F948E2&pcid=5B3AB970F71A803DEACDC0559115BFCF0A068CD97DD29835&cid=3ECA06F115476E3F&jid=BC473CEDCB8CE70D7B12BDD8EA00FF44&yid=FF7AA908D58E97FA&aid=0BF38A6680603574E70F22F2B23BC3B5&vid=&iid=E158A972A605785F&sid=4F2F18DD6F870C2C&eid=B9704B40A4225A24&fileno=20130417&flag=1&is_more=0">